Current Position:Home->Product Infomation  
AM1 Series MCCB
www.chinasonor.com  2014/5/16  
   1. Application
AM1 series moulded case circuit breaker is one of products developed and manufactured by adopting international advanced technology. It is supplied with rated insulating voltage 550 and 800V and used for circuit of AC 50/60Hz, rated operating voltage AC 400V (or below), rated operating current up to 1600A for infrequent changing over and starting of the motors.The products conforms to IEC60947-2 standard.

2. Main Technical Specification(table1)

 

Note: 6A without thermal protection 
The N-pole of four-poles breaker is sited at the right side of the product has four types: 
Type A: Without current trip-lease on N pole which making all the time, not closing and opening with the other three poles. 
Type B: Without current trip-release on N pole which closing and opening with the other poles. 
Type C: With current trip-release which closing and opening with the other three poles.
Type D: With current trip-release which making all the time not closing and opening with the other three poles. 

3. Protection Characteristic
The thermodynamic release of a circuit breaker provides the feature of inverse time-delay, while the magnetic release is the instantaneous operation as shown on table 2(distribution circuit breaker) and table 3 (motor protection circuit breaker).

4. Accessories of Circuit breaker
4.1 The external accessories of the breaker
Motor-driven operation device
1) Wiring diagram of type CDM electromagnetic operation device(fitting AM1-63,100,225) seethe following drawing (wiring diagram of the external accessories of the breaker in the dotted frame)



Code description: SB1 SB2 stand for push button.(provided by users themselves) Number "1" "2" "3" stand for number of wiring terminals.
Voltage rating: AC50Hz 230V 400V DC 220V
2) Wiring diagram of type CD motor-driven operation device (fitting AM1-400 630 800) seebelows (wiring diagram of the external accessories of the breaker in the dotted frame)

Code description: SB1 SB2 stand for push button. (provided by users themselves) "X" stands for line connection terminals
Voltage rating: AC50Hz 230V 400V DC 220V
Rotary handle operation device
The mechanism is used in moulded case circuit breaker to operate the draw-out panel. Powerdistribution panel and supply box outside the panel by turning the handle ,and to ensure thedoor of panel would not be openned when the breaker being on. The hand-drive mechanism can be equiped with two types of operation, one is "A" modelsquare handle , the other is "B" model round handle.



4.2 Release pattern and accessories code

SHT: Shunt release; UVR: Under-voltage release;AX: Auxiliary contact; AL: Alarm contact

Release patternand accessories code Name/Type AM1-63,
100, 225
AM1-400 AM1-630 AM1-800
200, 300 No accessories 200: magnetic release (only short circuit protection)300: thermal magnetic release(both overload and short circuit protection)
208, 308 Alarm contact
210, 310 Shunt release
220, 320 Auxiliary contact
230, 330 Under-voltage release
240, 340 Shunt release
Auxiliary contact
250, 350 Shunt release
Under-voltage release
260, 360 Two group of auxiliary contact
270,370 Under-voltage release
Auxiliary contact
218, 318 Shunt release
Alarm contact
228, 328 Alarm contact Auxiliary contact
238, 338 Under-voltage releaseAlarm contact
248, 348 Shunt release, Alarm contact,Auxiliary contact
268, 368 Two group of auxiliary contact,Alarm contact
278, 378 Shunt release, Alarm contact, Under-voltage release

According to user's demands, accessories could lead to direct wire outcoming or line wiringterminals could be added(please mark out in case of making order).
Under-voltage release
Wring diagram of the under-voltage module connected externally (the internal accessories inthe dotted frame)Ue: AC50Hz 230V, 400V

When the operation voltage is 35%~70% of the rated voltage, the under-voltage release shouldmake the breaker trip correctly.When the operation voltage is 85%~110% of the rated voltage, the under-voltage release shouldmake the breaker close.In case of the operation voltage less than 35% of the rated voltage, the under-voltage shouldprevent the breaker from closing.Note: Only the under-voltage release should be energized in advanced, the breaker could berecramped and turned-on, otherwise the breaker will be damaged.
Shunt release
Scheme of wiring(the internal accessories in the dotted frame)"K" is the slow motion switch normal-close contact connect the coil in series in the shunt release.It turns-on or turns-off voluntarily as soon as the breaker on or off.

Voltage rating: AC50Hz 230V or 400V, DC 110V 220VThe shunt release should make the breaker trip reliably when the operation voltage is 70%~110%of the rated control voltage.

 

 

 

 

 

 
 
YUEQING SONOR GROUP
ADD:Yueqing city, Zhejiang, China P.C:325603 E-MAIL:sale@chinasonor.com
TEL: 86-18066287511 MOB: 86-18066287511 FAX: 0577 MSN: happy2817
Copyright © 2009 www.chinasonor.com All Rights Reserved.  Technique Support:wzmywl.com
浙ICP备14013461号-1